750-0200-01 ACD GENie EC Portable Calibration Gas Generator
750-0200-01 ACD GENie EC Calibration Gas Generator for Cl2 CLO2 H2 H2S HCN


 
Base Price: $2,145.00

Availability: Usually Ships in 1 to 2 Weeks

ACD GENie EC Source



Qty:  
Description Technical Specs
 

ACD GENie EC Portable Calibration Gas Generator



Capable of generating Chlorine Cl2, Chlorine dioxide CLO2, Hydrogen H2, Hydrogen sulfide H2S, Nitrogen dioxide NO2 and Hydrogen cyanide HCN calibration gases.

750-0200-01 Advanced Calibration Designs GENie Electro Chemical Portable Calibration Gas Generator for Cl2, CLO2, H2, H2S, NO2 and HCN.

Originally released for high PPM hydrogen calibration gas (50-500 PPM), the GENie EC module now supports all of ACD’s electrochemical family of gases. This new release allows for a greatly expanded capability of your GENie system. The sources can be interchanged in the field to provide an array of calibration gases. Interchangeable calibration gases, combined with on-the-fly adjustable flow and concentration capabilities, make the GENie calibration system from ACD the most flexible and dynamic calibration system for all your sensor calibration needs. In addition, the GENie EC system provides for sample draw calibration utilizing a built in mass flow sensor to detect and adjust for varying sample draw rates for virtually any gas detection manufacturer you will need to calibrate. Please review the wide range of gases and concentrations listed below that the GENie EC supports.

The long lasting gas sources do not degrade on the shelf and provide the user with the equivalent of up to 100 cylinders worth of accurate calibration gas, making the GENie EC the smart choice for calibration of low to high PPM range gas detection equipment.


  • Adjustable gas concentrations created on demand
  • Integrated microprocessor controlled feedback
  • Long life generating sources
  • Non-hazardous transport
  • Expandable concentrations and gases
  • Ideal for demand flow or diffusion applications
Specifications
Gases and concentrations supported               See Drop Down Menu.
Air flow rate (with internal pump) 0.2 to 1 LPM
Sample draw rate (with pump disabled) 0.1 to 1.2 LPM
Source life 50 or 100 hours / source
Warm-up time (to 90%) Approx. 2 minutes
L x W x H 5”W x 3.88”H x 3.13”D
Weight 2 lb. (1360 g)
Operating temperature 0° C to 50° C
Relative humidity (intermittent use) 0 - 100%
Accuracy ±10%
Repeatability ±5%
Battery power 4 Alkaline “AA”
Battery life 8 hours (at .5 LPM flow rate)


Comes complete with GENie base unit (750-0200-01), GENie EC Source Module, 5 foot hose, nylon carrying case, batteries and manual. Source modules are interchangeable.