ACD MiniBump Bump Station- Intrinsically Safe
750-0401-00 Advanced Calibration Design MiniBump is an ultra-small Bump Tester or calibrator.
    Calibration or Bump Test Gas Generator for Chlorine Cl2, Hydrogen H2, Hydrogen sulfide H2S, and Hydrogen cyanide HCN.
-
Interchangeable calibration gases
- Automatic shut down after each test
- Alkaline battery powered
- Disposable generating source
- ATEX II3G EEx nL llB T4 approved
- CSA NRTL/C Exia T-6 approved intrinsically safe with CE Mark
Workers simply "bump" test their portable gas monitors, no matter the make or model; making sure your employees are working safely, properly, and are ready for use.
The MiniBump is the smallest, most lightweight and adaptive calibration gas source on the market. It is our lowest entry cost product as well as our simplest to use. It is certified to be intrinsically safe for operation on potentially explosive atmospheres. The MiniBump operates with interchangeable generating sources providing either fixed concentration output for calibration, or ‘bump’ output to drive your detector into alarm for operational verification.
Available in hydrogen sulfide, chlorine, hydrogen and hydrogen cyanide. The complete device fits into your shirt pocket and provides the equivalent of five 58 liter cylinders of gas with each generating source.
Intrinsically Safe
The Advanced Calibration Designs MiniBump is approved INTRINSICALLY SAFE by CSA NRTL/C Exia T-6. The Cal 2000 is CSA, ATEX and CE certified.
Cost Effective
The MiniBump cal gas generator uses only two "AA" alkaline batteries and easily fits inside your shirt pocket. Best of all, the MiniBump gas generator is extremely cost effective! The field replaceable electrochemical generating cell costs about as much as a disposable cylinder, but provides up to 1000 tests with no shelf life.
The MiniBump gas generators features include:
- Compact "shirt pocket" size
- Low power consumption
- Alkaline battery powered- two AA
|
- CSA certified Intrinsically safe
- Tracks cell usage
- Field replaceable generating cell
|
All MiniBump units are Certified for use in Intrinsically Safe Areas and is shipped with a rubber calibration cup, an instruction manual, and 2 AA alkaline batteries.
A Cl2, H2, H2S or HCN source must be used for the MiniBump to work properly.
** For use as a calibration source, please specify PPM range. If range is specified for Bump source, range will be ignored.
PHYSICAL FEATURES |
|
Size L x W xH |
4.09 x 2.36 x 1.18 in. |
Weight |
0.5 lbs |
Relative Humidity |
0-100% |
Operating Temperature |
0 to +50oC |
Certifications |
CE, ATEX, CSA |
Accuracy |
|
N/A |
Available Cell Generating Life |
Up to 1000 tests |
Non-hazardous Shipping |
Yes |
Interchangeable Gases |
Yes |
No Shelf Degradation |
Yes |
Mass Flow Feedback |
|
Battery Power |
2 alkaline AA |
Battery Life |
|
Approx. 10 hours |
|
|
Gases |
|
NH3 Ammonia |
10 - 150 ppm |
|
Cl2 Chlorine |
.05 - 1.0 ppm |
> 5.0 ppm |
.50 - 5.0 ppm |
ClO2 Chlorine dioxide |
.50 - 5.0 ppm |
|
C6H14 Hexane |
10 - 150 ppm |
|
H2 Hydrogen |
.05 - 50 ppm |
> 25 ppm |
50 - 1250 ppm |
H2S Hydrrogen sulfide |
.05 - 1.0 ppm |
> 25 ppm |
HCN Hydrogen cyanide |
.50 - 50 ppm |
> 10 ppm |
HCl Hydrogen chloride |
10 - 150 ppm |
|
O3 Ozone |
0.2 - 1.0 ppm |
|
C7H8 Toluene |
10 - 150 ppm |
|
|
|
|
 |