Honeywell Analytics Series 3000 MkII Flameproof Fixed Point Gas Monitor
Series 3000 MkII Flameproof, toxic and oxygen transmitter, Aluminum LM25
Series 3000 MkII is suited to a wide range of field applications and can detect toxic gases or Oxygen in a 2-wire 4-20mA format. This wiring configuration makes the Series 3000 MkII ideal for retrofitting older 2-wire devices. A combination of hazardous area approvals ensures that Series 3000 MkII can be wired alongside other Intrinsically Safe devices and still permit the ‘hot swap’ of a sensor, without the need to down-power the device or use a hot work permit. This type of certification approval also removes the need to segregate field wiring as required when IS (Intrinsic Safety) and Non IS field instruments are used in the same area, making the device both cost-effective and versatile. Series 3000 MkII also utilizes a magnetically activated user interface, permitting configuration and calibration without opening the enclosure or having to obtain a hot work permit.
Series 3000 MkII offers excellent reliability and ease of use with smart gas sensors which configure automatically when plugged into the transmitter. On board diagnostics provide a wealth of useful information during operation and fault finding routines. In addition, the patented ‘Reflex’ sensors test algorithms to ensure sensing elements are fitted and operational at all times. For extra flexibility, the remote sensor can be mounted up to 15m (50 feet) away from the transmitter making the Series 3000 MkII the ideal choice for applications where the point of detection is located in a hard-to-reach area, e.g. in high or low level concealed areas or inside a room with the transmitter located outside.
The gas sensors available for the Series 3000 MkII include Oxygen, Carbon Monoxide, Hydrogen Sulfide, Chlorine, Sulfur Dioxide, Chlorine Dioxide, Nitrogen Monoxide, Nitrogen Dioxide, Hydrogen, Hydrogen Fluoride, Ammonia and Phosphine. Further releases will include Hydrogen Chloride, Hydrogen Cyanide, EtO and Ozone. Series 3000 MkII is UL and c-UL certified.
Features
• Toxic and oxygen versions available
• New and retrofit applications
• Suitable for indoor or outdoor use
• Aluminum alloy explosion-proof housing
• IP66 as standard
Proven and Reliable Sensor Technology
• Surecel electrochemical sensors
• Poison immune infrared sensors
• Contained in a flameproof housing, used predominantly Zone 1 Applications
• Long life sensors
Approvals
UL/c-UL Class I, Div 1 & 2, Groups B, C & D; Class II, Div 1 Groups E, F, G, Class II, Div. 2, Groups F & G; Class I, Zone 1, Group IIB + H2 Hazardous Locations
Easy to Use
• User friendly and intuitive tri-color backlit display with digits, bar graph and icons
• Fully configurable via magnetic switches
• Optional remote sensor mounting
• Selectable sink or source 4-20mA output
• Auto-inhibit during maintenance
Cost Effective
• Common transmitter platform
• Minimal training required
• Reduced spares
• Non-intrusive, one-man operation
• Plug-in sensor replacement
Simple Installation
• Plug-in display module removes to give access to terminal area
• Integral mounting bracket
• ¾” NPT cable/conduit entries
• Removable plug/socket type terminal blocks for ease of wiring
• Sink/source switch to suit preferred wiring topology
Range of Optional Accessories
• Remote sensor mounting kit
• Remote sensor gassing kit
• Duct mounting kit
• Calibration gas flow housing
• Collecting cone
Applications
• Industrial manufacturing facilities
• Power plants
• Waste water facilities
• Utilities
• Food and beverage production
• Refineries and chemical plants
• Onshore oil and gas terminals
• Production platforms
• Exploration and drilling
Specifications:
Use
|
Rugged and reliable gas detector for the protection of personnel from toxic and oxygen gas hazards. Suitable for use in Zone 1 or 2 hazardous areas and North American Class I and II Division 1 or 2 areas.
|
ELECTRICAL
|
Input Voltage Range
|
17 to 24VDC (24VDC nominal)
|
Recommended Cable
|
2 wire with shield (90% coverage) or conduit; 0.5mm (20AWG) to 2.0mm (14AWG)
|
Signal
|
0-100%FSD 4-20mA; Fault = 3mA; Calibration due selectable off or 3mAMax. over range 22mA; Inhibit (toxic sensors) = Selectable 3mA or 4mA Inhibit; (Oxygen sensors) = Selectable 3mA or 17.4mA
|
|
|
|
|
CONSTRUCTION
|
Material
|
Housing: Epoxy painted aluminium alloy LM25
Sensor: 316 stainless steel
|
Weight (approx)
|
Aluminium Alloy LM25: 3.75lbs
|
Mounting
|
Integral mounting plate with 4 x mounting holes suitable for M8 bolts. Optional pipe mounting kit for horizontal or vertical pipe Ø1.5 to 3" (2" nominal)
|
Cable Entries
|
UL\cUL versions: 2 x ¾"NPT conduit entries. Suitable blanking plug supplied for use if only 1 entry used. Seal to maintain IP rating
|
ENVIRONMENTAL
|
|
IP Rating
|
IP66 in accordance with EN60529:1992, NEMA 4X
|
Certified Temperature Range
|
59°F to 86°F (15°C to 30°C)
|
Typical Part Numbers-
XNXXSA2SS - Ammonia (NH3) 0-1,000ppm (200 to 1,000ppm, 50ppm)
XNXXSA1SS - Ammonia (NH3) 0-200ppm (50 to 200ppm, 50ppm)
XNXXSC1SS - Carbon Monoxide (CO) 0-300ppm (100 to 999ppm, 100ppm)
XNXXSL1SS - Chlorine (Cl2) 0-5.0ppm (5.0 to 20.0ppm, 5.0ppm)
XNXXSX1SS - Chlorine Dioxide (ClO2) 0-1.00ppm
XNXXSG1SS - Hydrogen (H2) 0-1,000ppm
XNXXSG2SS - Hydrogen (H2) 0-10,000ppm
S3KXSR1SS - Hydrogen Chloride (HCl) 0-10ppm (10.0 to 20.0ppm, 1.0ppm)
S3KXSY1SS - Hydrogen Cyanide (HCN) 0-20.0ppm
XNXXSR1SS - Hydrogen Chloride (HCl) 0-10ppm (10.0 to 20.0ppm, 1.0ppm)
XNXXSF1SS - Hydrogen Fluoride (HF) 0-12.0ppm
XNXXSH2SS - Hydrogen Sulfide (H2S) 0-100ppm (50 to 500ppm, 10ppm)
XNXXSH1SS - Hydrogen Sulfide (H2S) 0-15ppm (10 to 50ppm, 1ppm)
XNXXSN1SS - Nitrogen Dioxide (NO2) 0-10.0ppm (5.0 to 50.0ppm, 5.0ppm)
XNXXSM1SS - Nitrogen Monoxide (NO) 0-100ppm
XNXXSO1SS - Oxygen (O2) 0-25%vol
XNXXSP1SS - Phosphine (PH3) 0-1.2ppm
XNXXSS1SS - Sulfur Dioxide (SO2) 0-15.0ppm (5.0 to 20.0ppm, 5.0ppm)